Available Tag State Parameters
Default State
Parameter | Available Options |
---|---|
Transmit rate | 0.1Hz, 0.20Hz, 0.50Hz, 1.0Hz, 2.0Hz |
Response mode | PowerSave |
Transmit power | Low(-12), Medium(-6), High(0), Maximum(6) |
State timeout | 30 s, 1 min, 5 min, 1 h, 4 h, 8 h, 24 h, Infinite |
Trigger sensitivity | 0..15, off |
Payloads | STA, TRIG, BAT, DEV (always active), ACC (configurable) |
Triggered State
Parameter | Available Options |
---|---|
Transmit rate | 1 Hz, 2 Hz, 3 Hz, 4 Hz, 5 Hz, 9 Hz |
Response mode | Fast, Balanced, PowerSave |
Transmit power | Low(-12), Medium(-6), High(0), Maximum(6) |
State timeout | 4 sec, 10 sec, 20 sec, 30 sec, 1 min |
Payloads | STA, TRIG, BAT, DEV (always active), ACC (configurable) |
Storage State
Parameter | Available Options |
---|---|
Trigger sensitivity | 0..15, off |
Temporary State
Temporary state settings are configured in Temporary command editor. For more information, see the Edit Temporary Command section.