Available Tag State Parameters

Default State

Table 1. Default State Parameters
Parameter Available Options
Transmit rate 0.1Hz, 0.20Hz, 0.50Hz, 1.0Hz, 2.0Hz
Response mode PowerSave
Transmit power Low(-12), Medium(-6), High(0), Maximum(6)
State timeout 30 s, 1 min, 5 min, 1 h, 4 h, 8 h, 24 h, Infinite
Trigger sensitivity 0..15, off
Payloads STA, TRIG, BAT, DEV (always active), ACC (configurable)

Triggered State

Table 2. Triggered State Parameters
Parameter Available Options
Transmit rate 1 Hz, 2 Hz, 3 Hz, 4 Hz, 5 Hz, 9 Hz
Response mode Fast, Balanced, PowerSave
Transmit power Low(-12), Medium(-6), High(0), Maximum(6)
State timeout 4 sec, 10 sec, 20 sec, 30 sec, 1 min
Payloads STA, TRIG, BAT, DEV (always active), ACC (configurable)

Storage State

Table 3. Storage State Parameters
Parameter Available Options
Trigger sensitivity 0..15, off

Temporary State